JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Thiemke, W A
Right arrow Articles by Wicher, K
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Thiemke, W A
Right arrow Articles by Wicher, K

 Previous Article  |  Next Article 

J Clin Microbiol. 1975 March; 1(3): 302-308

Laboratory experience with a radiometric method for detecting bacteremia.

W A Thiemke and K Wicher

ABSTRACT

Two bacteriologic systems for detecting bacteria in blood were compared; the automated radiometric BACTEC and the conventional method used in our laboratory for many years. BACTEC consisted of two bottles with 30 ml and the conventional method with 50 ml of media for aerobes and anaerobes. The BACTEC bottles were inoculated with 2 to 3 ml and the conventional with 4 to 5 ml of blood at the patient's bedside. Out of the 3,045 blood specimens cultured (804 patients), 262 (117 patients) were positive by one or both methods. The conventional system detected 5more cultures. The explanation of the differences is discussed. Positive blood cultures were detected by the BACTEC procedure as early as 6 h after the blood collection. In the first 24 h, on the average, 77% of aerobic organisms were detected by the BACTEC as compared to 48% by the conventional system. All anaerobic BACTEC cultures were positive within 4 days, whereas the conventional system detected at that time 74%. At day 4, 67% of fungi were detected by the BACTEC and only 27% by the conventional system. Of the 3,045 blood cultures examined by the BACTEC, 208 were recorded as false positive with growth index readings ranging from 30 to 59.


J Clin Microbiol. 1975 March; 1(3): 302-308







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1975 by the American Society for Microbiology. All rights reserved.