JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jenkins, R. D.
Right arrow Articles by Matsen, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jenkins, R. D.
Right arrow Articles by Matsen, J. M.
J Clin Microbiol. 1980 March; 11(3): 220-225

Rapid Semiautomated Screening and Processing of Urine Specimens

Ronald D. Jenkins1, DeVon C. Hale1,{dagger} and John M. Matsen1,2

1 Department of Pathology, University of Utah College of Medicine, Salt Lake City, Utah 84132
2 Department of Pediatrics, University of Utah College of Medicine, Salt Lake City, Utah 84132

ABSTRACT

A rapid urine culture procedure was evaluated in which positive urines were detected by using light-scatter photometry (Autobac). Specimens were analyzed at 3, 5, and 6 h. Specimens detected as positive at 3 h were then further evaluated by a direct 3-h susceptibility procedure (Autobac) and by a 4-h identification procedure (Micro-ID). Of 949 specimens, 175 had >105 colony-forming units per ml by colony count. Of these latter specimens, 75.4% had been detected by 3 h, and 95.4% were detected by 6 h. Of specimens positive by Autobac at 3 h, 96% (95.7%) had >105 colony-forming units per ml. If pure by Gram stain, those positive specimens were inoculated to direct susceptibility and identification systems. When direct Autobac susceptibilities were compared with the standard Autobac method done from the plate the following day, discrepancy rates were 1.3% very major, 2.1% major, and 7.4% total. The direct identifications were 94% (94.2%) correct when using the Micro-ID manual and a collection of octal patterns unique to this system, in which urine/broth culture inoculum was employed instead of the usual organism colony suspension. Those urine specimens negative after screening at 3 h were evaluated at 5 and 6 h, and an additional 126 specimens were detected as positive. These were then processed by routine plate inoculation, due to the limitations of the work day. By 6 h, 95.4% of specimens with >105 colony-forming units per ml were detected. The 4.6% false-negative results consisted of patients on antibiotics, or slowly growing bacteria suspected of being distal urethral contaminants. Thus, 83.5% of the urine cultures received by 9:00 a.m. (10.6% 3-h positives and 72.9% negative at 6 h) could be evaluated and reported within one 8-h work day.


FOOTNOTES

{dagger} Present address: Infectious Disease and Clinical Microbiology, Riverview Hospital, Idaho Falls, ID 83401.


J Clin Microbiol. 1980 March; 11(3): 220-225







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1980 by the American Society for Microbiology. All rights reserved.