JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Seip, W F
Right arrow Articles by Evans, G L
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Seip, W F
Right arrow Articles by Evans, G L
J Clin Microbiol. 1980 March; 11(3): 226-233

Atmospheric analysis and redox potentials of culture media in the GasPak System.

W F Seip and G L Evans

ABSTRACT

Oxygen and carbon dioxide concentrations, internal atmospheric pressure, catalyst temperature, and time of appearance of water condensate were monitored for various time intervals at ambient (20 to 25 degrees C) temperature in a GasPak 100 Anaerobic System (BBL Microbiology Systems, Cockeysville, Md). Simultaneously, the redox potential (Eh) of various plated culture media in the system was also measured. The oxygen concentration was reduced to less than 0.4% in 100 min. The Eh of the media, corrected for hydrogen ion, reached -100 mV within 60 to 100 min, and the carbon dioxide concentration increased to between 4 and 7% in 60 min, depending on the number of plates of media present. Condensate appeared generally between 10 and 15 min, and the temperature of the lid reached a maximum between 20 and 40 min. Condensate time and lid temperature increase are important early indicators of a correctly functioning GasPak System. A characteristic pressure-vacuum-pressure profile is produced as a result of controlled release of hydrogen and carbon dioxide gases and the reaction of hydrogen and oxygen to produce water. Anaerobic conditions were achieved well before the methylene blue anaerobic indicator became decolorized, which required more than 6 h at 20 to 25 degrees C. At this time the Eh of media in the jar was well below -200 mV. Since the indicator is reduced within 5 h at 35 degrees C, the Eh of media in the jar would also be expected to decrease more rapidly at the higher temperature.


J Clin Microbiol. 1980 March; 11(3): 226-233