JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Holland, R L
Right arrow Articles by McCracken, A W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Holland, R L
Right arrow Articles by McCracken, A W

 Previous Article  |  Next Article 

J Clin Microbiol. 1980 August; 12(2): 180-184

Automated detection of microbial growth in blood cultures by using stainless-steel electrodes.

R L Holland, B H Cooper, N G Helgeson and A W McCracken

ABSTRACT

Sterile stainless-steel electrodes implanted in blood culture bottles and monitored electronically were used to detect growth of microorganisms. Each blood culture bottle contained 100 ml of medium and was inoculated with 10 ml of blood seeded with either 300 or 50 colony-forming units of one of several bacterial or yeast species that are commonly isolated from clinical blood cultures. Growth was indicated by a voltage change of at least 0.1 mV/min with an increasing slope over at least three consecutive 15-min intervals. This method was compared to the conventional visual method for detecting microbial growth in broth. Growth detection by both techniques was confirmed by subculture to solid media. Of the 163 cultures seeded with the high inoculum (300 colony-forming units) and confirmed as being positive, 148 (90.8%) were positive by the electronic detection system (EDS). At the lower inoculum (50 colony-forming units), 47 of 53 (88.7%) positive cultures were detected by EDS. Twelve of the 21 false-negatives by the EDS were cultures seeded with Cryptococcus neoformans. Excluding C. neoformans, the rate of detection of growth was 96.0%. Microbial growth was detected an average of 18 h earlier by EDS than by the conventional system in 176 (90.2%) of the cultures. Also examined were 156 patient blood cultures: 13 were positive both by EDS and by conventional methods.


J Clin Microbiol. 1980 August; 12(2): 180-184