JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Craythorn, J M
Right arrow Articles by Garibaldi, R A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Craythorn, J M
Right arrow Articles by Garibaldi, R A
J Clin Microbiol. 1980 August; 12(2): 250-255

Membrane filter contact technique for bacteriological sampling of moist surfaces.

J M Craythorn, A G Barbour, J M Matsen, M R Britt and R A Garibaldi

ABSTRACT

We used a membrane filter contact technique to pick up and grow bacteria from artificially contaminated surfaces. We were able to recover individual colony-forming units (CFU) of Staphylococcus aureus from a moist agar surface more efficiently with 3- and 5- micron membrane filters than with Rodac plates, velvet pads, velveteen pads, or smaller-pore membrane filters. The effective transfer of bacteria with the 3- and 5-micron membrane filters was 0.96 +/- 0.04 (standard error of the mean) and 0.99 +/- 0.04, respectively, as compared to 0.49 +/- 0.03 for Rodac plates, 0.09 +/- 0.01 velvet pad imprints, 0.05 +/- 0.01 for velveteen pad imprints, 0.27 +/- 0.02 for velvet pad rinses, 0.005 +/- 0.001 for velveteen pad rinses, 0.39 +/- 0.02 for 0.45-micron filters, and 0.85 +/-0.05 for 1.2 micron filters. In addition, the recovery of S. aureus from contaminated bovine muscle surfaces with the 5-microns membrane filter was similar to that of quantitative dilutions of biopsy material and was significantly higher than the recovery from Rodac plates. The 5-microns membrane filters on a paddle recovered 52 +/- 5 CFU/cm2 from artificially contaminated bovine skeletal muscle, the quantitative dilutions of biopsy recovered 69 +/- 5 CFU/cm2, and the Rodac plate recovered 5 +/- 3 CFU/cm2. Sampling of moist surfaces by the membrane filter contact technique is easy to perform and highly efficient; our data suggest that it could be employed for cultures of clinical surfaces such as surgical wounds or burns.


J Clin Microbiol. 1980 August; 12(2): 250-255







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1980 by the American Society for Microbiology. All rights reserved.