JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Holmes, C J
Right arrow Articles by Walter, C W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Holmes, C J
Right arrow Articles by Walter, C W
J Clin Microbiol. 1980 December; 12(6): 725-731

Potential hazards associated with microbial contamination of in-line filters during intravenous therapy.

C J Holmes, R B Kundsin, R K Ausman and C W Walter

ABSTRACT

The survival and multiplication of Enterobacter agglomerans, Klebsiella pneumoniae, Serratia marcescens, and Pseudomonas aeruginosa in 0.45- and 0.22-micrometer in-line filter sets during simulated infusions were studied to evaluate the ability of each filter type to prevent infusions of these bacteria into patients. Bacteria were found to proliferate in the upstream compartment of sets housing both filter porosities. None of the 0.22-micrometer in-line filters were penetrated by the test bacteria. In contrast, P. aeruginosa was observed to penetrate each 0.45-micrometer in-line filter examined within 12 h of continuous infusion. Tribe Klebsielleae organisms penetrated a proportion of the 0.45-micrometer filters usually between 48 and 72 h of infusion. In addition, the elution of endotoxin from gram-negative bacteria trapped in the filter set during infusion is reported. Collected infusion filtrate exhibited a trend of increasing endotoxin-like activity with an increasing duration of infusion. In the case of E. agglomerans, mean peak levels of approximately 65 pg of Escherichia coli endotoxin per ml were attained after 72 h. Other bacteria produced similar results, except mean peak levels ranged from 5 to 30 pg/ml. It was noted that endotoxin-like activity was not detected in filtrate eluted from contaminated filter sets during the initial 24 h of infusion. We conclude that to avoid potential hazards of bacterial penetration and endotoxin production during continuous use of in-line filter sets, the 0.22-micrometer filter type must be employed and replaced every 24 h.


J Clin Microbiol. 1980 December; 12(6): 725-731







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1980 by the American Society for Microbiology. All rights reserved.