JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gallo, D
Right arrow Articles by Emmons, R W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gallo, D
Right arrow Articles by Emmons, R W

 Previous Article  |  Next Article 

J Clin Microbiol. 1981 April; 13(4): 631-636

Multiple-antigen slide test for detection of immunoglobulin M antibodies in newborn and infant sera by immunofluorescence.

D Gallo, J L Riggs, J Schachter and R W Emmons

ABSTRACT

A microimmunofluorescence test was evaluated for use in measuring immunoglobulin M (IgM) antibodies in infant sera to five of the agents implicated in congenital and neonatal disease. Pen point dots of Toxoplasma gondii, cytomegalovirus, rubella virus, herpes simplex virus, and chlamydial cell culture antigens were applied to each circle of eight-circle printed slides. These multiple-antigen slides greatly facilitated the screening of 607 sera from infants and 117 sera from mothers for the presence of IgM antibody to these agents. Forty sera could be examined microscopically in approximately 30 min. All sera reacting with one or more antigens were tested for rheumatoid factor by the latex method, absorbed with glutaraldehyde-cross-linked human IgG, and retested for the presence of IgM antibody. IgM antibody to cytomegalovirus was demonstrated in sera from four newborns, but IgM antibody to rubella virus could not be detected until 21 days after birth, although rubella virus was isolated from sera from five younger infants. This may indicate that rubella IgM levels in many congenitally infected newborns are too low to be measured by the immunofluorescence method. Five percent of the sera from infants in this study possessed demonstrable IgM antibody to one of the antigens.


J Clin Microbiol. 1981 April; 13(4): 631-636







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1981 by the American Society for Microbiology. All rights reserved.