JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Collins, M M
Right arrow Articles by Stites, D P
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Collins, M M
Right arrow Articles by Stites, D P

 Previous Article  |  Next Article 

J Clin Microbiol. 1982 March; 15(3): 456-464

Solid-phase Clq-binding fluorescence immunoassay for detection of circulating immune complexes.

M M Collins, C H Casavant and D P Stites

ABSTRACT

A fluorescence immunoassay for detection of immune complexes bound to solid-phase C1q was developed. The method was standardized by using human aggregated immunoglobulin G (IgG) to simulate immune complexes. A linear relationship existed between the concentrations of the aggregated IgG standards and the resulting fluorescent intensity. The method was found to be reproducible and capable of detecting as little as 10 micrograms of aggregated IgG per ml of heat-inactivated human serum. Antigen-antibody complexes prepared in vitro were detectable from equivalence to moderate antigen excess. Endogenous serum C1q inhibited the binding of aggregated IgG to solid-phase C1q. Pretreatment of test sera with EDTA was ineffective in eliminating this competitive effect. Heating the sera at 56 degrees C alleviated, but did not abolish, interference of endogenous C1q. Elevated levels of immune complexes were detectable in sera fro seven of nine patients wit systemic lupus erythematosus, provided the samples were heat inactivated before testing. Heparin and DNA were also found to interfere with the detection of aggregated IgG added to human serum. Assay values were falsely decreased due to competitive inhibition by these anions. Lipopolysaccharides from a variety of bacterial preparations produced no detectable interference. A comparative study was conducted on samples that had previously been tested by fluid-phase C1q-binding radioimmunoassay. The two methods were concordant in assigning normal or elevated levels of immune complexes in 70% of the samples tested. This solid-phase fluorescence immunoassay is proposed as a possible alternative to radioimmunoassay for the detection of circulating immune complexes.


J Clin Microbiol. 1982 March; 15(3): 456-464







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1982 by the American Society for Microbiology. All rights reserved.