JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pezzlo, M. T.
Right arrow Articles by De La Maza, L. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pezzlo, M. T.
Right arrow Articles by De La Maza, L. M.
J Clin Microbiol. 1982 March; 15(3): 468-474

Screening of Urine Cultures by Three Automated Systems

Marie T. Pezzlo, Grace L. Tan, Ellena M. Peterson and Luis M. De La Maza

Division of Medical Microbiology, Department of Pathology, University of California Irvine Medical Center, Orange, California 92668

ABSTRACT

A study was conducted to compare three automated systems and the Gram stain for their ability to detect significant bacteriuria. A total of 1,000 urine specimens were evaluated by Autobac MTS (General Diagnostics), Auto Microbic system (AMS; Vitek Systems, Inc.), and MS-2 (Abbott Laboratories) and compared with a semiquantitative culture plate method. Two hundred thirty-nine (23.9%) specimens had colony counts of >105 colony-forming units (CFU)/ml by the culture plate method (group I). Of these, 204 (85.3%) were positive by Autobac, 198 (82.8%) were positive by AMS, and 179 (74.9%) were positive by MS-2. When pure cultures of diphtheroids, lactobacilli, and viridans streptococci not group D were considered contaminants and therefore excluded, there were 118 specimens containing pure cultures of probable pathogens. The percentage of significant isolates detected was 97.4% (115 of 118) by the Gram stain, 96.6% (114 of 118) by Autobac, and 95.8% (113 of 118) by AMS and MS-2. The average detection time for all organisms was 2.2 h by Autobac, 6.1 h by AMS, and 1.8 h by MS-2; therefore, all three methods were more rapid than the 18- to 24-h standard plate culture method. One hundred sixty-one (16.1%) specimens had colony counts of 104 to 105 CFU/ml (group II). The probable pathogens not detected in this group were two (1.2%) by Autobac and MS-2 and three by AMS (1.9%). The average detection time for group II was 4.2 h by Autobac, 8.9 h by AMS, and 3.8 h by MS-2. Six hundred specimens had colony counts of <104 CFU/ml. Of these, 188 had colony counts equal to 103 and <104 CFU/ml (group III), and 412 cultures were below detectable limits by the standard plate method (group IV). Less than 37 and 15% of groups III and IV, respectively, were detected by instrumentation. Average detection times for groups III and IV were 4.6 and 4.8 h by Autobac, 10 and 11 h by AMS, and 4.2 and 4.4 h by MS-2. The cost of supplies and technical time with Gram stain, Autobac, and MS-2, when used as screening methods, were comparable and considerably less expensive than for the reference method. The AMS was the least expensive system when the cost for identifying probable pathogens was included.


J Clin Microbiol. 1982 March; 15(3): 468-474