JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kelly, M T
Right arrow Articles by Balfour, L C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kelly, M T
Right arrow Articles by Balfour, L C

 Previous Article  |  Next Article 

J Clin Microbiol. 1982 May; 15(5): 902-905

Comparison of three automated systems for antimicrobial susceptibility testing of gram-negative bacilli.

M T Kelly, J M Latimer and L C Balfour

ABSTRACT

Several instruments for automated or semiautomated susceptibility testing are currently available. Three of these instruments, Autobac (General Diagnostics, Warner-Lambert Co., Morris Plains, N.J.), MS-2 (Abbott Laboratories, Dallas, Tex.), and AutoMicrobic system (AMS) (Vitek, Inc., Hazelwood, Mo.) were compared for antimicrobial susceptibility testing of gram-negative bacilli. A total of 207 isolates representing 29 species of gram-negative bacilli were tested simultaneously by each instrument and by a standardized disk diffusion reference method. Nine antimicrobial agents, including ampicillin, carbenicillin, cephalothin, gentamicin, tobramycin, amikacin, tetracycline, trimethoprim-sulfamethoxazole, and nitrofurantoin were tested. Discrepancies between the results of the automated and reference disk diffusion methods were resolved by agar dilution testing. Overall, 93% of the Autobac and MS-2 results and 83% of the AMS results were in agreement with the results obtained by the reference methods. The results of the Autobac, MS-2, and AMS systems respectively included 3.3, 2.3, and 4.2% major and very major discrepancies. Excessive testing discrepancies were found for certain drugs, including ampicillin, tetracycline, and nitrofurantoin, and for certain organisms, including species of Providencia, Serratia, and Citrobacter. The results of this comparison of three automated systems for antimicrobial susceptibility testing indicate that the Autobac and MS-2 instruments provided highly reliable results. The AMS need further development of its susceptibility testing capability to eliminate an unacceptably high number of minor discrepancies.


J Clin Microbiol. 1982 May; 15(5): 902-905







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1982 by the American Society for Microbiology. All rights reserved.