JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jones, R N
Right arrow Articles by Thornsberry, C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jones, R N
Right arrow Articles by Thornsberry, C
J Clin Microbiol. 1982 July; 16(1): 153-163

Evaluation of the MICUR system for quantitative antimicrobial susceptibility testing: a multiphasic comparison with reference methods.

R N Jones, A L Barry, J Bigelow, T L Gavan and C Thornsberry

ABSTRACT

Four laboratories participated in a three-phase study to evaluate the MICUR antimicrobial broth microdilution system (Boehringer Mannheim Diagnostics, Inc., Houston, Tex.). The dried-antimicrobial agent MICUR system was compared with a reference broth microdilution method (National Committee for Clinical Laboratory Standards) by using 304 recently isolated clinical strains and two collections of stock or challenge organisms. Of 7,092 minimum inhibitory concentration (MIC) datum pairs derived from the clinical isolates, 96.6% were within an acceptable (+/- 1 log2 dilution) range. MICUR MICs agreed with the reference broth microdilution method MICs in 95.3% of 6,840 MIC pair determinations performed on stock or challenge cultures. The MICUR intralaboratory reproducibility within +/- 1 log2 dilution step for the clinical isolates was 98.4%. The MICUR intralaboratory and interlaboratory reproducibilities for 26 stock cultures were 98.4 and 95.1%, respectively. For 180 challenge cultures (4,199 MIC pairs) which were included in the MICUR testing to provide a wide variety of antimicrobial susceptibility and resistance patterns, the results for 92.5% were in close agreement with the reference broth microdilution results. No specific resistance mechanism went unrecognized by this new commercial system. The MICUR system gives comparable MIC results when evaluated against the reference broth microdilution method, and it would be acceptable for use in clinical microbiology laboratories.


J Clin Microbiol. 1982 July; 16(1): 153-163