JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Johnson, J E
Right arrow Articles by Jorgensen, J H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Johnson, J E
Right arrow Articles by Jorgensen, J H
J Clin Microbiol. 1982 August; 16(2): 299-302

Evaluation of the macro-vue latex agglutination test for quantitation of gentamicin in human serum.

J E Johnson, S Crawford and J H Jorgensen

ABSTRACT

The Macro-Vue Card Test (Hynson, Wescott, and Dunning, Baltimore, Md.) for rapid quantitation of gentamicin in serum was compared with bioassay and radioimmunoassay procedures on sera from 100 patients. Regression analysis of paired results from the bioassay (using Klebsiella pneumoniae ATCC 27799) and the Macro-Vue Card Test indicated a correlation coefficient of 0.89, whereas comparing radioimmunoassay and Card Test results yielded a correlation coefficient of 0.83. The bioassay-radioimmunoassay correlation coefficient was 0.88. The data were further examined by grouping the sera of the patients into three categories based on therapeutic concentration ranges as follows: less than 2 micrograms/ml, subtherapeutic range; 2 to 8 micrograms/ml, therapeutic range; greater than 8 micrograms/ml, potentially toxic range. Of 100 specimen values, 81 fell into the same concentration range when bioassay and Card Test values were compared. Of the 19 disagreements, 12 were considered minor. Of 100 specimen values compared by radioimmunoassay and the Card Test, 88 fell into the same concentration range. Of the 12 disagreements, 6 were considered minor. Therefore, the Macro-Vue Card Test for gentamicin compared favorably with both the bioassay and radioimmunoassay procedures. The minimal time required to perform the Card Test (12 to 15 min) makes it attractive for situations in which immediate results are needed.


J Clin Microbiol. 1982 August; 16(2): 299-302