JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fletcher, M A
Right arrow Articles by Latif, Z
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fletcher, M A
Right arrow Articles by Latif, Z
J Clin Microbiol. 1982 August; 16(2): 307-313

Horse erythrocyte glycoprotein-latex reagent that reacts with infectious mononucleosis heterophile antibody.

M A Fletcher, K E Caldwell, L Saez and Z Latif

ABSTRACT

A sialoglycoprotein from horse erythrocytes was isolated in essentially homogeneous form and found to contain the neuraminidase-sensitive determinant of the horse erythrocyte for Paul-Bunnell heterophile antibodies of infectious mononucleosis. This reactivity was retained after covalent coupling of the antigen to latex particles. The latex reagent has greater stability (greater than 3 years) than either fresh or preserved horse erythrocytes. It can be used in a direct slide test; no absorption of the serum is necessary. The new test compared favorably with some standard tests for infectious mononucleosis antibody which use horse erythrocytes. Agreement of the latex test with the absorbed fresh horse cell test was 100%, and agreement with a stabilized horse erythrocyte spot test was 94%. The latex test also agreed 100% with a radioimmunoassay for the detection of heterophile antibody with 125I-labeled horse erythrocyte glycoprotein. The new latex test was compared with a bovine erythrocyte glycoprotein-latex test, and a correlation of 94% was observed. In addition, it was compared with the Wöllner test (enzyme-treated sheep cell-absorbed sheep cell agglutination test) with which it agreed in 92% of samples tested.


J Clin Microbiol. 1982 August; 16(2): 307-313







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1982 by the American Society for Microbiology. All rights reserved.