JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Burke, D. S.
Right arrow Articles by Ussery, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Burke, D. S.
Right arrow Articles by Ussery, M. A.
J Clin Microbiol. 1982 December; 16(6): 1034-1042
Copyright © 1982, American Society for Microbiology. All Rights Reserved.

Antibody Capture Immunoassay Detection of Japanese Encephalitis Virus Immunoglobulin M and G Antibodies in Cerebrospinal Fluid

Donald S. Burke, Ananda Nisalak and Michael A. Ussery

Department of Virology, U.S. Component, Armed Forces Research Institute of Medical Sciences, Pramongkutklao Hospital, Bangkok 4, Thailand

ABSTRACT

Immunoglobulin M (IgM) and IgG antibodies to Japanese encephalitis virus (JEV) were detected in acute-phase cerebrospinal fluid (CSF) specimens from patients with acute encephalitis by using a solid-phase radioimmunoassay of the antibody capture type. Of 12 patients with JEV infections subsequently proven by hemagglutination inhibition serology, 11 had JEV IgM antibodies, as measured by antibody capture radioimmunoassay, in the first CSF specimen (geometric mean titer, 1:2,500) compared with 0 of 8 patients with acute encephalitis proven not to be due to JEV. Specific IgM anti-JEV activity (units per microgram) was greater in CSF than in parallel serum specimens in all 11 positive cases by more than fourfold on the average (range, 1.4 to 13). Among seven patients with broadly reactive hemagglutination inhibition seroresponses typical of persons previously exposed to other flaviviruses, six had high levels of JEV IgG antibodies (as measured by antibody capture radioimmunoassay) in their acute-phase CSF (geometric mean titer, 1:26,000), whereas in five patients experiencing their first flavivirus infection, JEV IgG antibodies measured by antibody capture radio-immunoassay were either absent (one patient) or weakly reactive (four patients; geometric mean titer, 1:3,200). Specific IgG anti-JEV activity was greater in CSF than in parallel serum specimens in eight of the nine positive cases measured (range, 1.3- to 24-fold). The antibody capture solid-phase immunoassay approach is well suited for detecting specific antibody activity in CSF.


J Clin Microbiol. 1982 December; 16(6): 1034-1042
Copyright © 1982, American Society for Microbiology. All Rights Reserved.