JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hoban, D J
Right arrow Articles by Ronald, A R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hoban, D J
Right arrow Articles by Ronald, A R
J Clin Microbiol. 1983 June; 17(6): 1061-1065

Urine screening with the MS-2.

D J Hoban, J C Koss, C A Gratton and A R Ronald

ABSTRACT

A study was undertaken to evaluate the effectiveness of the MS-2 (Abbott Laboratories, Dallas, Tex.) in screening urine specimens in a large clinical laboratory. A total of 15,319 urine specimens (9,954 midstream specimens and 5,365 catheter specimens) were evaluated with the MS-2 and by a surface streak procedure. The study was conducted in two phases, differing in that phase II urine specimens were evaluated in the MS-2 by using a program software update (03.01). For midstream urine specimens, MS-2 detection rates in phases I and II were, respectively, 94.5 and 94.3% at a plate count of greater than 10(5) CFU/ml, 74.4 and 65.3% at plate counts of 5 X 10(4) to 1 X 10(5) CFU/ml, 55.0 and 52.4% at plate counts of 1 X 10(4) to 5 X 10(4) CFU/ml, 31.2 and 20.5% at plate counts of 10(3) to 10(4) CFU/ml, and 15.7 and 6.4% at plate counts of less than 10(3) CFU/ml. For catheter urine specimens, the MS-2 detection rates in phases I and II were, respectively, 95.4 and 96.8% at plate counts greater than 10(5) CFU/ml, 74.4 and 85.7% at plate counts of 5 X 10(4) to 1 X 10(5) CFU/ml, 50.0 and 44.4% at plate counts 10(4) to 5 X 10(4) CFU/ml, 25.6 and 14.9% at plate counts of 10(3) to 10(4) CFU/ml, and 14.7 and 5.2% at plate counts less than 10(3) CFU/ml.


J Clin Microbiol. 1983 June; 17(6): 1061-1065







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1983 by the American Society for Microbiology. All rights reserved.