J Clin Microbiol. 1983 September; 18(3): 535-538
Inactivation of hepatitis B virus by intermediate-to-high-level disinfectant chemicals.
W W Bond,
M S Favero,
N J Petersen and
J W Ebert
ABSTRACT
In five separate tests, hepatitis B virus in dried human plasma was exposed for 10 min at 20 degrees C to disinfectant chemicals having activity levels ranging from intermediate (e.g., 70% isopropyl alcohol) to high (e.g., 2% aqueous glutaraldehyde at pH 8.6). Five chimpanzees (one animal per disinfectant chemical) received treated material intravenously, and none showed signs of infection after post-inoculation periods of 9 months. Two animals were rechallenged with inoculum treated in the same manner, except that saline was used instead of a disinfectant chemical; both were infected within 4 weeks. Our results showed that hepatitis B virus was not as resistant to disinfectant chemicals as once thought and suggested that chemicals with similar activity levels (intermediate to high) might possibly be used on hepatitis B virus contamination with a margin of safety.
J Clin Microbiol. 1983 September; 18(3): 535-538
This article has been cited by other articles:
-
Kampf, G., Kramer, A.
(2004). Epidemiologic Background of Hand Hygiene and Evaluation of the Most Important Agents for Scrubs and Rubs. Clin. Microbiol. Rev.
17: 863-893
[Abstract]
[Full Text]
-
Culver, D. A., Gordon, S. M., Mehta, A. C.
(2003). Infection Control in the Bronchoscopy Suite: A Review of Outbreaks and Guidelines for Prevention. Am. J. Respir. Crit. Care Med.
167: 1050-1056
[Full Text]
-
Vyas, A, Pickering, C A C, Oldham, L A, Francis, H C, Fletcher, A M, Merrett, T, Niven, R M.
(2000). Survey of symptoms, respiratory function, and immunology and their relation to glutaraldehyde and other occupational exposures among endoscopy nursing staff. Occup. Environ. Med.
57: 752-759
[Abstract]
[Full Text]
-
Beltrami, E. M., Williams, I. T., Shapiro, C. N., Chamberland, M. E.
(2000). Risk and Management of Blood-Borne Infections in Health Care Workers. Clin. Microbiol. Rev.
13: 385-407
[Abstract]
[Full Text]
-
BSG ENDOSCOPY COMMITTEE WORKING PARTY,
(1998). Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a Working Party of the British Society of Gastroenterology Endoscopy Committee. Gut
42: 585-593
[Abstract]
[Full Text]
-
Quebbeman, E. J., Telford, G. L., Condon, R. E.
(1989). The Threat of AIDS in the Operating Room. PERSPECT VASC SURG ENDOVASC THER
2: 121-129
Copyright © 1983 by the American Society for Microbiology. All rights reserved.