JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Thomson, R B
Right arrow Articles by Washington, J A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Thomson, R B, Jr
Right arrow Articles by Washington, J A, 2nd

 Previous Article  |  Next Article 

J Clin Microbiol. 1984 February; 19(2): 97-99

Contamination of cultures processed with the isolator lysis-centrifugation blood culture tube.

R B Thomson Jr, S J Vanzo, N K Henry, K L Guenther and J A Washington 2nd

ABSTRACT

Overall contamination (on- plus off-streak) of the Isolator (Du Pont Co.) blood culture tube (23%) was greater than that of a conventional broth blood culture bottle (0.6%) or that of a biphasic blood culture bottle (1.3%). To determine the source of this contamination, Isolator cultures of blood from 59 healthy volunteers and of sterile broth from 60 vials were made. A total of 37% of the blood cultures and 22% of the broth cultures were contaminated (P = 0.06). Staphylococcus epidermidis-contaminated cultures represented 31 and 10% of the blood and broth cultures, respectively (P = 0.06). Contamination of plates processed on a bench top, in front of horizontal laminar flow, and in a biological safety cabinet with vertical laminar flow were compared. Processing plates in a biological safety cabinet resulted in a significant reduction in the number of contaminated plates (P less than 0.05). The contamination rate for 7,874 Isolator blood cultures processed in the biological safety cabinet was significantly decreased to 6.7% on-streak (9.3% on- plus off-streak). Contamination of Isolator-processed blood cultures originated from the laboratory and the patient. The former can be reduced by inoculating plates in a vertical laminar flow biological safety cabinet and by maintaining adequate quality control of media. The latter may be unavoidable.


J Clin Microbiol. 1984 February; 19(2): 97-99