JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Christensson, B
Right arrow Articles by Kronvall, G
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Christensson, B
Right arrow Articles by Kronvall, G

 Previous Article  |  Next Article 

J Clin Microbiol. 1984 May; 19(5): 680-686

Methodological aspects of Staphylococcus aureus peptidoglycan serology: comparisons between solid-phase radioimmunoassay and enzyme-linked immunosorbent assay.

B Christensson, F Espersen, S A Hedström and G Kronvall

ABSTRACT

In the present studies we compared the ability of two commonly used assays, solid-phase radioimmunoassay and enzyme-linked immunosorbent assay (ELISA), to detect human antibodies to Staphylococcus aureus peptidoglycan. ELISA was superior, with a reproducibility of 12.0%, as compared with 18.1% in solid-phase radioimmunoassay. Much lower serum dilutions could be used in ELISA. We also studied the effects of solubilizing the antigen by lysostaphin, lysozyme, or ultrasonication. Lysostaphin-treated peptidoglycan cannot be recommended since solid-phase radioimmunoassay could not distinguish positive from negative serum samples with this preparation. On the other hand, the sensitivity in both assays was high when peptidoglycan treated with lysozyme for 240 min or with ultrasonication for 30 min was used as antigen. The interassay correlation between solid-phase radioimmunoassay and ELISA was slightly better with sonicated peptidoglycan (correlation coefficient = 0.94, P less than 0.01), as compared with lysozyme-treated peptidoglycan (correlation coefficient = 0.76, P less than 0.01). We recommend the ELISA with sonicated peptidoglycan as antigen for use in routine serology.


J Clin Microbiol. 1984 May; 19(5): 680-686







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1984 by the American Society for Microbiology. All rights reserved.