JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hughes, J H
Right arrow Articles by Hamparian, V V
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hughes, J H
Right arrow Articles by Hamparian, V V

 Previous Article  |  Next Article 

J Clin Microbiol. 1984 September; 20(3): 441-447

Latex immunoassay for rapid detection of rotavirus.

J H Hughes, A V Tuomari, D R Mann and V V Hamparian

ABSTRACT

A latex agglutination (LA) test was evaluated for the detection of human rotaviruses in stool specimens. Both antiserum and immunoglobulin G (IgG)-sensitized latex particles were used, with IgG-coated beads being more sensitive for human rotavirus antigen detection. Latex beads sensitized with anti-simian-SA-11 IgG were stable for at least 8 months when stored at 4 degrees C. The sensitivity of the test was compared with that of the Rotazyme (Abbott Laboratories, Diagnostics Div., North Chicago, Ill.) test. The least number of particles detected was 9.0 X 10(5) particles by the LA test versus 4.5 X 10(5) particles by the Rotazyme test. When 10 stool specimens were serially diluted for antigen endpoint determinations, the geometric mean titer by the LA test was 592 versus 1,280 by the Rotazyme test. Forty-three stool samples positive by the Rotazyme test were all positive by the LA test, and no false negative results were detected. Unconfirmed false positive reactions ranged between 8 and 24%. The LA test for rotavirus antigen detection is direct, easy to perform, sensitive, quick, and may have application for use in diagnostic laboratories, emergency rooms, and physician's offices.


J Clin Microbiol. 1984 September; 20(3): 441-447