JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hanvanich, M
Right arrow Articles by Yolken, R H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hanvanich, M
Right arrow Articles by Yolken, R H

 Previous Article  |  Next Article 

J Clin Microbiol. 1985 February; 21(2): 184-188

Stool desorbing activity: a possible cause of false-positive reactions in competitive enzyme immunoassays.

M Hanvanich, R Viscidi, B E Laughon, J G Bartlett and R H Yolken

ABSTRACT

We have developed a competitive enzyme immunoassay for the measurement of purified toxin A of Clostridium difficile. However, when we applied this assay to the detection of C. difficile toxin in stool specimens, we noted a high rate of nonspecific activity in fecal specimens which did not contain toxin. We found that the low specificity (26%) of the assay was due to the presence in stool specimens of interfering factors which desorbed the antigen coated on the solid-phase surface. These factors could be detected by measurement of the desorption of biotin-labeled proteins attached to the solid-phase surface. In addition, these interfering factors were partially inactivated by heating at 56 degrees C for 10 min and partially inhibited by phenylmethylsulfonyl fluoride (2 mM) or soybean trypsin inhibitor (10 mg/ml). These data suggested that the desorbing activity was due to proteolytic activity in the fecal specimens. Fetal calf serum (50%) was found to be the most effective measure in preventing the interfering effect. By using 50% fetal calf serum as a diluent, we increased the specificity of the antibody inhibition enzyme immunoassay to 93%. Interfering factors in stool specimens could be a cause of false-positive results in other competitive immunoassay systems. The use of diluents which neutralize protease activity can result in a marked improvement in the specificity of competitive immunoassay systems.


J Clin Microbiol. 1985 February; 21(2): 184-188







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1985 by the American Society for Microbiology. All rights reserved.