JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nachum, R
Right arrow Articles by Berzofsky, R N
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nachum, R
Right arrow Articles by Berzofsky, R N

 Previous Article  |  Next Article 

J Clin Microbiol. 1985 May; 21(5): 759-763

Chromogenic Limulus amoebocyte lysate assay for rapid detection of gram-negative bacteriuria.

R Nachum and R N Berzofsky

ABSTRACT

A chromogenic Limulus amoebocyte lysate assay was evaluated as a rapid screening test for the detection of clinically significant gram-negative bacteriuria. The development of a distinctive yellow color after the addition of chromogenic substrate to the Limulus amoebocyte lysate-urine reaction mixture was used to measure greater than or equal to 10(5) gram-negative bacteria per ml. A total of 324 urine specimens were assayed, with 68 gram-negative urinary tract infections identified as defined by quantitative urine colony counts of greater than or equal to 10(5) bacteria per ml. Of these, 68 and 67 of 68 were detected by the chromogenic Limulus amoebocyte lysate assay at urine dilutions of 1:10 and 1:20, respectively. Nine false-positive chromogenic Limulus amoebocyte lysate assay results were observed at both urine dilutions and in the same specimens. At a urine dilution of 1:10, sensitivity and specificity were 100 and 96.6%, respectively, with predictive values of 100% for a negative test and 88.3% for a positive test. At a urine dilution of 1:20, sensitivity and specificity were 98.6 and 96.6%, respectively; predictive values were 99.6% for a negative test and 88.3% for a positive test. These data suggest that chromogenic Limulus amoebocyte lysate assay of urine has potential usefulness as a rapid, reliable, and easily performed and interpreted screening test for the diagnosis of clinically significant gram-negative bacteriuria.


J Clin Microbiol. 1985 May; 21(5): 759-763







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1985 by the American Society for Microbiology. All rights reserved.