JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pfaller, M A
Right arrow Articles by Koontz, F P
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pfaller, M A
Right arrow Articles by Koontz, F P

 Previous Article  |  Next Article 

J Clin Microbiol. 1985 May; 21(5): 783-787

Use of rapid screening tests in processing urine specimens by conventional culture and the AutoMicrobic system.

M A Pfaller and F P Koontz

ABSTRACT

Two rapid urine screening tests, the Chemstrip LN (BioDynamics, Indianapolis, Ind.) and the Bac-T-Screen urine screening device (Marion Laboratories, Inc., Kansas City, Mo.), were evaluated as techniques to predict bacteriuria as quantitated by either conventional culture or the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). A total of 666 urine specimens were analyzed by both screening tests as well as the AutoMicrobic system and quantitative culture. The sensitivities of both Chemstrip LN and Bac-T-Screen for the detection of low levels of bacteriuria (greater than or equal to 10(3) CFU/ml) were comparable (73.3 and 74.4%, respectively) and were too low to recommend their use as a primary urine screen. Their excellent predictive value of a negative result at the 10(5) CFU/ml level (96 and 97.5%, respectively) makes them potentially useful in predicting urine specimens with less than 10(5) CFU/ml. The use of either of these tests in combination with the AutoMicrobic system markedly decreased the time required to classify urine specimens. Their low cost relative to the AutoMicrobic system urine card makes the use of either test cost effective as a screen for the AutoMicrobic system.


J Clin Microbiol. 1985 May; 21(5): 783-787







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1985 by the American Society for Microbiology. All rights reserved.