JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fung, J C
Right arrow Articles by Tilton, R C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fung, J C
Right arrow Articles by Tilton, R C

 Previous Article  |  Next Article 

J Clin Microbiol. 1985 November; 22(5): 748-753

Comparison of the detection of herpes simplex virus in direct clinical specimens with herpes simplex virus-specific DNA probes and monoclonal antibodies.

J C Fung, J Shanley and R C Tilton

ABSTRACT

A comparison of two commercially available kits for rapid herpes simplex virus (HSV) detection directly in patient specimens was performed. The immunofluorescence assay (IFA) utilized monoclonal antibodies to HSV, and the DNA probe assay utilized three HSV sequences cloned into pBR322. A sample of 243 specimens received in viral transport medium were inoculated into MRC-5 tissue cultures. The remainder of the specimen was centrifuged, and the cellular pellet was examined by IFA and DNA probes. One hundred and sixty-two (66.7%) specimens were considered satisfactory for IFA and DNA probe testing, based on a criterion of observing greater than or equal to 2 intact cells per high-power field. Of the 162 specimens, 35 (21.6%) yielded HSV by culture. By IFA, the sensitivity of detecting HSV culture-positive specimens was 77.1%; specificity was 100%, positive predictive value was 100%, and negative predictive value was 93.3%. DNA probe sensitivity was 71.4%; specificity was 90.6%; positive predictive value was 67.6%; and negative predictive value was 92%. Forty-four (27.2%) of the 162 specimens exhibited nonspecific cytoplasmic staining with the DNA probe. IFA and DNA probe assays can be completed in 2 to 3 h, whereas the average time to culture positivity in this series was 2.2 days. Rapid HSV diagnosis can aid in timely and appropriate patient management.


J Clin Microbiol. 1985 November; 22(5): 748-753







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1985 by the American Society for Microbiology. All rights reserved.