JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Doern, G V
Right arrow Articles by Blacklow, N R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Doern, G V
Right arrow Articles by Blacklow, N R

 Previous Article  |  Next Article 

J Clin Microbiol. 1986 February; 23(2): 226-229

Detection of rotavirus with a new polyclonal antibody enzyme immunoassay (Rotazyme II) and a commercial latex agglutination test (Rotalex): comparison with a monoclonal antibody enzyme immunoassay.

G V Doern, J E Herrmann, P Henderson, D Stobbs-Walro, D M Perron and N R Blacklow

ABSTRACT

A total of 176 human fecal specimens were examined for the presence of rotavirus by four different assays: a monoclonal antibody enzyme immunoassay; the original polyclonal antibody enzyme immunoassay marketed by Abbott Laboratories, North Chicago, Ill. (Rotazyme I); a modification of this assay which is now commercially available (Rotazyme II); and a latex agglutination test (Rotalex) recently introduced by Medical Technology Corp., Somerset, N.J. In addition, selected specimens were examined for the presence of rotavirus by electron microscopy, immune electron microscopy, and RNA gel electrophoresis. A total of 40 specimens were positive in the monoclonal antibody enzyme immunoassay, and 136 were negative. Using the results obtained with this procedure as the reference standard, we found the sensitivities of the Rotazyme I, Rotazyme II, and Rotalex tests to be 97.4, 100, and 81.6%, respectively. The specificities of these three procedures were 88.8, 83.9, and 100%, respectively.


J Clin Microbiol. 1986 February; 23(2): 226-229