JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Henry, D
Right arrow Articles by Smith, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Henry, D
Right arrow Articles by Smith, J

 Previous Article  |  Next Article 

J Clin Microbiol. 1986 April; 23(4): 718-724

Comparative evaluation of four systems for determining susceptibility of gram-positive organisms.

D Henry, L Kunzer, J Ngui-Yen and J Smith

ABSTRACT

A study was undertaken to compare four commercial systems for testing the antimicrobial susceptibility patterns of gram-positive cocci. The reference method was an agar dilution method. The systems evaluated were the MS-2 system (Abbott Diagnostics Div., Mississauga, Ontario), the AutoMicrobic system (AMS) (Vitek Systems, Inc., Hazelwood, Mo.) with the gram-positive susceptibility (GPS) card, the Sceptor system (BBL Microbiology Systems, distributed by Becton Dickenson, Canada Inc., Mississauga, Ontario), and the Micro-Media system (Beckman Instruments, Inc., Anaheim, Calif.). There was a greater than 98% essential accord (EA) between all test results and the reference method results when testing 134 isolates of Staphylococcus aureus. In testing 79 isolates of coagulase-negative staphylococci the EA was greater than 97% with all systems except the MS-2. In the MS-2 system only, 30% of tests were interrupted by the instrument because of insufficient growth in the control chamber. Excluding the Sceptor system, the EA was greater than 96% on testing 70 isolates of enterococcus. In testing 15 isolates of group B Streptococcus there was 91% EA with the AMS and Sceptor systems and only 71 and 88% EA with the MS-2 and Micro-Media systems, respectively. The new AMS GPS MIC card was tested against 29 methicillin-resistant S. aureus, 10 coagulase-negative staphylococci, and 9 enterococci, and it gave more accurate results than the earlier GPS breakpoint card. The Micro-Media and MS-2 systems did not reliably detect marginally methicillin-resistant S. aureus. The MS-2 was the least expensive system to operate on a cost per test basis ($3.59 Can.), whereas the Sceptor was the most expensive system ($5.29 Can.). The AMS ws the least labor intensive (0.9 min per test), and the Sceptor system was the most time consuming (2.9 min per test).


J Clin Microbiol. 1986 April; 23(4): 718-724




This article has been cited by other articles: