JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Franson, T R
Right arrow Articles by Sohnle, P G
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Franson, T R
Right arrow Articles by Sohnle, P G

 Previous Article  |  Next Article 

J Clin Microbiol. 1986 October; 24(4): 559-561

Persistent in vitro survival of coagulase-negative staphylococci adherent to intravascular catheters in the absence of conventional nutrients.

T R Franson, N K Sheth, L Menon and P G Sohnle

ABSTRACT

The in vitro survival of coagulase-negative staphylococci in media devoid of routine nutritional supplementation was assessed in the presence and absence of catheter materials to evaluate bacterium-device interactions. Strains of slime- and non-slime-producing coagulase-negative staphylococci were suspended in phosphate-buffered saline together with multiple segments of polyvinyl chloride (PVC), Teflon, Silastic, and polyurethane catheters and in control suspensions without catheters. Catheters were removed at 2 min and 24, 48, 72, and 96 h of incubation and washed thoroughly, and semiquantitative roll cultures were performed on blood agar. In addition, after 96 h catheters were introduced into tryptic soy broth (TSB), and roll cultures were performed after 18 h of incubation. Results demonstrated that after 96 h, 6 of 32 catheter specimens (4 PVC) had greater than 10 CFU of coagulase-negative staphylococci per catheter; after TSB addition, 18 of 32 catheter specimens had greater than or equal to 100 CFU per catheter (8 of 8 PVC catheters had greater than 1,000 CFU per catheter). In control suspensions, no growth was seen at 96 h or after TSB addition. No differences in the survival of slime- versus non-slime-producing strains were observed in control or catheter studies. These findings suggest that both slime- and non-slime-producing coagulase-negative staphylococci survive in vitro on catheters (especially PVC) in the absence of conventional nutrients and can proliferate on catheters when nutrients are added. Catheter-adherent coagulase-negative staphylococci appear to possess survival mechanisms under adverse conditions which may relate to the genesis of occult foreign-body-associated infections.


J Clin Microbiol. 1986 October; 24(4): 559-561




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1986 by the American Society for Microbiology. All rights reserved.