JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Moriarty, R A
Right arrow Articles by Fischer, G W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moriarty, R A
Right arrow Articles by Fischer, G W

 Previous Article  |  Next Article 

J Clin Microbiol. 1987 February; 25(2): 259-262

Rapid detection of group B streptococcal antigen in human amniotic fluid.

R A Moriarty, L P Smith, V G Hemming and G W Fischer

ABSTRACT

Infants exposed in utero to group B streptococcus (GBS)-infected human amniotic fluid (HAF) are at high risk for serious infection. Latex particle agglutination (LPA) tests are not approved for detection of GBS in HAF. Two LPA systems, Patho-Dx Strep B and Wellcogen Strep B, were used to test unfiltered sterile HAF and filtered HAF containing concentrations of GBS carbohydrate from 0.2 to 100 micrograms/ml. Four different processing techniques were used to prevent nonspecific LPA: EDTA, nitrous acid, enzyme, and nitrous acid-heat. GBS (10(2) CFU/ml) was inoculated into filtered HAF, incubated, sampled serially, processed with enzyme, and tested by LPA. Unprocessed, unfiltered HAF showed 33% nonspecific agglutination when tested by LPA. Processing of HAF removed nonspecific agglutination and improved GBS antigen detection. Without processing, LPA could not detect less than 100 micrograms of GBS carbohydrate per ml. With nitrous acid or enzyme processing, as little as 0.2 microgram/ml could be detected. Results were easier to read after enzyme processing than after nitrous acid processing. Although both LPA systems were equally efficient, testing was easier with the Patho-Dx system. After enzyme processing, LPA could detect as few as 10(4) CFU/ml when agglutination was read with a 4 X hand lens. Substances in HAF induce false-positive reactions during LPA testing. Processing removes the interference and improves the detection of GBS. LPA testing of HAF may allow earlier identification and treatment of infants at risk for serious GBS infection.


J Clin Microbiol. 1987 February; 25(2): 259-262







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1987 by the American Society for Microbiology. All rights reserved.