JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hanson, C W
Right arrow Articles by Fernandes, P B
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hanson, C W
Right arrow Articles by Fernandes, P B

 Previous Article  |  Next Article 

J Clin Microbiol. 1987 June; 25(6): 1079-1082

Regression analysis, proposed interpretative zone size standards, and quality control guidelines for a new macrolide antimicrobial agent, A-56268 (TE-031).

C W Hanson, R Bailer, E Gade, R A Rode and P B Fernandes

ABSTRACT

A-56268 is a 6-O-methyl derivative of erythromycin A which has a spectrum of activity similar to that of erythromycin and is 1 log2 dilution more potent than erythromycin against most organisms that have been tested. The correlation of zone size diameters and MICs of A-56268 for 461 strains of bacteria isolated from clinical specimens was investigated. Based on anticipated levels in human serum of 2 micrograms/ml, 15-microgram disks have been recommended with zone size standards of greater than or equal to 15 mm for susceptibility (MIC correlate, less than or equal to 2.0 micrograms/ml) and less than or equal to 11 mm for resistance (MIC correlate, greater than or equal to 8 micrograms/ml). Selection of these tentative breakpoints resulted in no very major errors (false susceptible), a major error (false resistant) rate of 0.22%, and an acceptable minor error (intermediate) rate of 2.82%. MIC ranges and zone diameter limits for quality control organisms used in the standardized agar dilution and disk diffusion susceptibility tests with A-56268 are given.


J Clin Microbiol. 1987 June; 25(6): 1079-1082







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1987 by the American Society for Microbiology. All rights reserved.