JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Barry, A L
Right arrow Articles by Jones, R N
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Barry, A L
Right arrow Articles by Jones, R N
J Clin Microbiol. 1988 November; 26(11): 2415-2420

Variability of clarithromycin and erythromycin susceptibility tests with Haemophilus influenzae in four different broth media and correlation with the standard disk diffusion test.

A L Barry, P B Fernandes, J H Jorgensen, C Thornsberry, D J Hardy and R N Jones

Clinical Microbiology Institute, Tualatin, Oregon 97062.

ABSTRACT

Four separate laboratories performed antimicrobial susceptibility tests with 40 Haemophilus influenzae isolates, each tested in triplicate. Erythromycin and a new macrolide, clarithromycin (A-56268; TE-031), were tested by the disk diffusion method, by the agar dilution procedure in two different media, and by broth microdilution tests in four different media. Erythromycin MICs for 90% of the strains were 16 micrograms/ml in Mueller-Hinton broth with 3% lysed horse blood and NAD, 4.0 micrograms/ml in hemophilus test medium, and 2.0 micrograms/ml in supplemented Schaedler broth or in the fastidious broth medium from Beckman Instruments, Inc. Clarithromycin MICs were generally 1 doubling dilution greater than erythromycin MICs in each of the media. Erythromycin disk tests corresponded best with MICs determined in the fastidious broth medium. In that same medium, clarithromycin MICs were about 1 doubling dilution greater than what would be expected from the results of disk tests. Because there were fewer growth failures, hemophilus test medium is recommended for microdilution tests with H. influenzae. Incubation of all tests for a full 24 h without an increased CO2 atmosphere was needed to achieve maximal precision of the tests. Interlaboratory and intralaboratory reproducibility of all tests was satisfactory.


J Clin Microbiol. 1988 November; 26(11): 2415-2420




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1988 by the American Society for Microbiology. All rights reserved.