JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Waris, M
Right arrow Articles by Obert, G
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Waris, M
Right arrow Articles by Obert, G
J Clin Microbiol. 1988 December; 26(12): 2581-2585

Time-resolved fluoroimmunoassay compared with virus isolation for rapid detection of respiratory syncytial virus in nasopharyngeal aspirates.

M Waris, P Halonen, T Ziegler, S Nikkari and G Obert

Department of Virology, University of Turku, Finland.

ABSTRACT

Two monoclonal antibodies against two distinct conserved epitopes of the respiratory syncytial virus (RSV) nucleocapsid protein were used in a direct time-resolved fluoroimmunoassay (TR-FIA) for the detection of RSV antigens in nasopharyngeal aspirates. The capture antibody was adsorbed to the solid phase of microdilution strip wells, and the indicator antibody was labeled with a europium chelate. Specimens and label were incubated simultaneously for 1 h at 37 degrees C in the coated wells. After the test samples were washed, fluorescence enhancement solution was added, strips were shaken, and the time-resolved fluorescence was measured. The test procedure took only 75 min, and the total time for 20 specimens, with pretreatment by sonication, was 2 to 3 h. We prospectively evaluated the detection of RSV in nasopharyngeal aspirates of pediatric patients by TR-FIA and by virus isolation in human diploid fibroblasts. TR-FIA detected 40 of 42 isolation-positive specimens. Nine additional isolation-negative specimens were positive by TR-FIA; all proved to be true positives by a blocking-type confirmatory assay. The sensitivity, specificity, positive predictive value, and negative predictive value for TR-FIA were 95, 96, 82, and 99%, respectively, of the values obtained by virus isolation and 96, 100, 100, and 99%, respectively, of the values obtained by virus isolation and the confirmatory assay.


J Clin Microbiol. 1988 December; 26(12): 2581-2585