JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gustafsson, B
Right arrow Articles by Andersson, M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gustafsson, B
Right arrow Articles by Andersson, M

 Previous Article  |  Next Article 

J Clin Microbiol. 1988 February; 26(2): 188-193

Production and characterization of monoclonal antibodies directed against Bordetella pertussis lipopolysaccharide.

B Gustafsson, U Lindquist and M Andersson

Department of Vaccine Production, National Bacteriological Laboratory, Stockholm, Sweden.

ABSTRACT

Hybrid cell lines producing monoclonal antibodies against Bordetella pertussis lipopolysaccharide (LPS) were established. The specificity of the antibodies was ascertained by enzyme-linked immunosorbent assay (ELISA) and ELISA-inhibition experiments with LPS and delipidated polysaccharide fragments (PS-1 and PS-2) prepared from B. pertussis LPS. Monoclonal antibody 9-1-H5 reacted with B. pertussis LPS only, whereas monoclonal antibodies 6-4-H6 and 9-2-A8 reacted with PS-1 and PS-2 as well as B. pertussis LPS. The antibodies did not react with LPS prepared from B. parapertussis and B. bronchiseptica in an LPS-specific ELISA. A monoclonal antibody-based sandwich ELISA was developed for detection of B. pertussis LPS. This assay had a detection limit of B. pertussis LPS in concentrations ranging from 0.16 to 0.32 microgram/ml. The assay was also shown to be specific for the detection of whole B. pertussis bacteria. No cross-reactions were observed with strains of Branhamella catarrhalis, Neisseria meningitidis, Streptococcus miteor, Haemophilus influenzae, or Legionella pneumophila. The monoclonal antibodies might be useful for the detection of soluble antigens and whole bacteria in clinical samples and for studies of the immunochemical structure of B. pertussis LPS.


J Clin Microbiol. 1988 February; 26(2): 188-193




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1988 by the American Society for Microbiology. All rights reserved.