JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sakata, H
Right arrow Articles by Sugiura, A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sakata, H
Right arrow Articles by Sugiura, A
J Clin Microbiol. 1988 April; 26(4): 636-640

Passive hemagglutination test for measles immunity and serodiagnosis.

H Sakata and A Sugiura

Department of Measles Virus, National Institue of Health, Tokyo, Japan.

ABSTRACT

A passive hemagglutination (PHA) test for measles was evaluated in comparison with hemagglutination inhibition (HI) and neutralization (NT) tests. The PHA test determines exclusively the level of antibody directed to the hemagglutinin protein of measles virus. The ratio of PHA to HI titer was 1 to 32 (geometric mean, 6.5) for the first 5 weeks of infection but declined to near unity thereafter. It gradually increased again to 4 to 32 (geometric mean, 11.7) over several years. The initial high PHA titer relative to the HI titer was most likely due to the presence of the immunoglobulin M antibody known to be efficient in agglutination, because 2-mercaptoethanol (2ME) treatment of sera reduced the PHA titer to a level similar to that of the HI titer. The PHA titer in sera obtained after the convalescent phase was insensitive to 2ME, and the relative increase in the PHA over the HI titer was presumably a result of increased antibody avidity. In some individuals, the HI titer fell to below detectable levels several years after either natural infection or vaccination, but the PHA as well as the NT titer remained positive. The PHA titer was therefore a more reliable and more sensitive indicator of immune status against measles than the HI titer. The decrease in PHA titer by 2ME treatment provided evidence of a current or very recent infection. PHA was found to be useful both for assessing immunity status and for serodiagnosis.


J Clin Microbiol. 1988 April; 26(4): 636-640







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1988 by the American Society for Microbiology. All rights reserved.