JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nicolle, L E
Right arrow Articles by Murray, D
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nicolle, L E
Right arrow Articles by Murray, D

 Previous Article  |  Next Article 

J Clin Microbiol. 1988 June; 26(6): 1115-1119

Urine specimen collection with external devices for diagnosis of bacteriuria in elderly incontinent men.

L E Nicolle, G K Harding, J Kennedy, M McIntyre, F Aoki and D Murray

Department of Medicine, University of Calgary, Winnipeg, Manitoba, Canada.

ABSTRACT

We determined the validity of using external devices for urine specimen collection from 24 elderly incontinent men residing in a nursing home by collecting three sequential specimens, two with external devices and then one by catheterization. The positive predictive value of organisms isolated in quantitative counts of greater than or equal to 10(5) CFU/ml in external devices for bladder bacteriuria was 86% for either sterile or clean collecting devices and 93% for the same organism in two consecutive specimens. The negative predictive value for organisms present in quantitative counts of less than 10(5) CFU/ml was 90% for both sterile and clean devices and 86% when the organism was present in both specimens. Contamination in external collection devices was not influenced by whether the device was clean or sterile, circumcision of the resident, or duration of time between device application and specimen collection. These data suggest that urine specimens collected by ward nursing staff with external devices are reliable for the diagnosis of bacteriuria in this patient population.


J Clin Microbiol. 1988 June; 26(6): 1115-1119




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1988 by the American Society for Microbiology. All rights reserved.