JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ozanne, G
Right arrow Articles by Fauvel, M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ozanne, G
Right arrow Articles by Fauvel, M
J Clin Microbiol. 1988 August; 26(8): 1496-1500

Performance and reliability of five commercial enzyme-linked immunosorbent assay kits in screening for anti-human immunodeficiency virus antibody in high-risk subjects.

G Ozanne and M Fauvel

Laboratoire de sante publique du Quebec, Canada.

ABSTRACT

Anti-human immunodeficiency virus enzyme-linked immunosorbent assay kits marketed by Electro-Nucleonics Inc. (ENI), Genetic Systems Corp. (GSC), Organon Teknika Inc. (OTI), Ortho Diagnostic Systems Inc. (ODSI), and Wellcome Diagnostics (WD) were evaluated by using 289 randomly selected serum samples from a high-risk population and 53 serum samples likely to produce false-positive results. The radioimmunoprecipitation assay was used as the reference test. Sensitivities ranged from 96.51% (ODSI, WD) to 97.67% (ENI, GSC, OTI). Sera showing antibodies to viral glycoproteins only produced the false-negative results. Specificities ranged from 99.6% (ENI, GSC, ODSI, OTI) to 100% (WD). False-positive results were obtained with sera from patients with autoimmune disease or Epstein-Barr virus infection. Only results from GSC and OTI kits were distributed in two compact clusters well segregated on either side of the cutoff point. ODSI and GSC kits had the best intralot reproducibility. The GSC kit had the best interlot reproducibility. Cutoff values for ODSI and GSC kits were the least variable. Intraplate repeatability was good for all kits. Sample localization was not an important source of variability. Our results do not point out one outstanding kit among the five evaluated. However, the GSC kit showed the best overall results.


J Clin Microbiol. 1988 August; 26(8): 1496-1500




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1988 by the American Society for Microbiology. All rights reserved.