JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Segura, M
Right arrow Articles by Sitges-Serra, A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Segura, M
Right arrow Articles by Sitges-Serra, A

 Previous Article  |  Next Article 

J Clin Microbiol. 1989 December; 27(12): 2656-2659

In vitro bacteriological study of a new hub model for intravascular catheters and infusion equipment.

M Segura, C Alía, L Oms, J J Sancho, J M Torres-Rodríguez and A Sitges-Serra

Department of Surgery, Hospital Universitari Nostra Senyora del Mar, Spain.

ABSTRACT

We investigated in vitro the antibacterial properties of a simulated new hub model in which the female part has an antiseptic chamber through which the needle (male part) must pass before connection of the set and the catheter. To establish the time needed for disinfection, the magnitude of reduction of the contaminating inocula by the new hub model, and the antibacterial properties of the different components of the hub, we used needles contaminated with solutions containing high inocula (1.9 x 10(7) to 1.2 x 10(11) CFU/ml) of microorganisms involved in hub-related catheter sepsis. Sterilization of the needles was accomplished by allowing them to remain in the antiseptic chamber for 10 s in all assays with Staphylococcus epidermidis, Pseudomonas aeruginosa, Escherichia coli, and Candida albicans. The rubber closures limiting the antiseptic chamber and the dilution effect of the antiseptic itself accounted for a minor part of the inoculum reduction achieved by the new hub model. This simulated hub provides good protection against endoluminal contamination. Further studies seem warranted to prove its industrial viability and clinical efficacy.


J Clin Microbiol. 1989 December; 27(12): 2656-2659







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1989 by the American Society for Microbiology. All rights reserved.