JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kudlac, J
Right arrow Articles by McKee, G L
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kudlac, J
Right arrow Articles by McKee, G L

 Previous Article  |  Next Article 

J Clin Microbiol. 1989 June; 27(6): 1303-1306

Development of quality control procedures for the human immunodeficiency virus type 1 antibody enzyme-linked immunosorbent assay.

J Kudlac, S Hanan and G L McKee

Public Health Laboratory, Oklahoma State Department of Health, Oklahoma City 73124.

ABSTRACT

A standardized pool of human sera that was positive for human immunodeficiency virus type 1 (HIV-1) antibody was developed. This positive control serum was used to analyze test differences among eight laboratories, among the HIV-1 antibody test kits of three different manufacturers, among different lots of the same test kit, and among pipetting devices and techniques. The standardized pool of human sera was tested 327 times by the different laboratories. In terms of positive tests, a reproducibility of 99.69% was achieved; however, significant test variance among laboratories, among test kit lots, and among pipetting devices and techniques could be demonstrated if the tests were compared on the basis of the net positive optical density (OD) value. This value was calculated by subtracting the cutoff OD value (i.e., the value below which an OD value was considered negative for HIV-1 antibody) from the observed OD value of the standardized pool of human sera. The results obtained suggest that this strategy can be used for proficiency testing, for monitoring the quality of HIV-1 antibody enzyme-linked immunosorbent assay reagents, and for evaluating pipetting devices and techniques.


J Clin Microbiol. 1989 June; 27(6): 1303-1306







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1989 by the American Society for Microbiology. All rights reserved.