JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kline, R L
Right arrow Articles by Quinn, T C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kline, R L
Right arrow Articles by Quinn, T C

 Previous Article  |  Next Article 

J Clin Microbiol. 1989 July; 27(7): 1449-1452

Evaluation of human immunodeficiency virus seroprevalence in population surveys using pooled sera.

R L Kline, T A Brothers, R Brookmeyer, S Zeger and T C Quinn

National Institute of Allergy and Infectious Diseases, Bethesda, Maryland 20892.

ABSTRACT

The pooling of individual serum samples to determine human immunodeficiency virus (HIV) seropositivity was examined to assess whether testing pooled sera was technically feasible, cost-effective, and accurate for estimating seroprevalence in large population surveys. The sensitivities and specificities of three commercially available HIV enzyme-linked immunosorbent assay (ELISA) kits were tested using 65 serum pools of 15 individual serum samples each (975 total serum samples) at two different dilutions. With pooled sera, the Organon Teknika Bio-EnzaBead ELISA at half the dilution recommended by the manufacturer showed the best agreement with ELISA and Western blot results of individual sera. In subsequently testing 92 pools, each containing 15 individual serum samples from a population of American patients attending a sexually transmitted diseases clinic, the estimated seroprevalence was 5.27 compared with 4.93% in a test of 1,380 individual serum samples and 5.19% in a test of 4,028 individual serum samples from the same population. In an evaluation of 1,380 African patients using 10 serum samples per pool, the estimated seroprevalence was 5.79 compared with 6.16% in a test of individual sera. These results indicate that ELISA testing with pooled sera is highly sensitive and specific and appears to be a cost-effective means for estimating HIV seroprevalence in large population-based surveys.


J Clin Microbiol. 1989 July; 27(7): 1449-1452




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1989 by the American Society for Microbiology. All rights reserved.