JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Farzadegan, H
Right arrow Articles by Polk, B F
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Farzadegan, H
Right arrow Articles by Polk, B F

 Previous Article  |  Next Article 

J Clin Microbiol. 1989 August; 27(8): 1882-1884

Performance of serological assays for early detection of human immunodeficiency virus type 1 seroconversion.

H Farzadegan, E Taylor, W Hardy, N Odaka and B F Polk

Department of Epidemiology, Johns Hopkins University School of Hygiene and Public Health, Baltimore, Maryland 21205.

ABSTRACT

Early detection of sexually transmitted human immunodeficiency virus type 1 (HIV-1) infection was investigated in newly infected persons to determine the sensitivities of currently available serologic techniques. Serial serum samples were obtained from 51 newly infected persons in a cohort of 1,153 homosexual or bisexual men participating in the Baltimore Center of the Multi-Center AIDS Cohort Study during the first 2.5 years of follow-up. Of 51 participants, 45 seroconverted between any two seminannual visits and 6 were found to have been infected just prior to study entry. Five enzyme-linked immunosorbent assays (ELISAs), two immunoblots, and an HIV-1 P24 antigen capture assay were performed on a panel of all serial serum samples from these individuals. The sensitivity of ELISAs varied between 50 and 84% in seroconverters with less-developed antibody response. In this group of seroconverters, the most sensitive antibody assay was an immunoblot from Biotech (95%) and HIV-1 P24 was found infrequently (9.5%). The sensitivities of ELISAs and immunoblot were 100% in individuals with more-developed antibody patterns, and no HIV-1 P24 was detected among them.


J Clin Microbiol. 1989 August; 27(8): 1882-1884







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1989 by the American Society for Microbiology. All rights reserved.