JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Segura, M
Right arrow Articles by Sitges-Serra, A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Segura, M
Right arrow Articles by Sitges-Serra, A

 Previous Article  |  Next Article 

J Clin Microbiol. 1990 November; 28(11): 2551-2554

Assessment of a new hub design and the semiquantitative catheter culture method using an in vivo experimental model of catheter sepsis.

M Segura, C Alía, J Valverde, G Franch, J M Torres Rodríguez and A Sitges-Serra

Department of Surgery, Hospital Universitari Nostra Senyora del Mar, Barcelona, Spain.

ABSTRACT

An in vivo model of hub-related catheter sepsis in rabbits is reported. The model was used to investigate the protection offered by a new hub design against external contamination by Pseudomonas aeruginosa or Staphylococcus epidermidis and to reassess the diagnostic value of the semiquantitative culture method in bacteremia of endoluminal origin. Contamination of conventional Luer-Lock connectors was followed by clinical sepsis, positive catheter segment cultures, or both, whereas contamination of the new hub was followed by complete protection. Clinical and bacteriological discrepancies observed between contamination with P. aeruginosa and S. epidermidis suggest that the virulence of microorganisms may account for differences in the natural history of hub-originated catheter sepsis. The semiquantitative extraluminal method for catheter culture yielded less than 15 CFU in three animals with proven bacteremia and should not be used as the "gold standard" to define catheter-related bacteremia.


J Clin Microbiol. 1990 November; 28(11): 2551-2554




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1990 by the American Society for Microbiology. All rights reserved.