JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Seppänen, H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Seppänen, H

 Previous Article  |  Next Article 

J Clin Microbiol. 1990 April; 28(4): 719-723

Development of a highly specific and sensitive rubella immunoglobulin M antibody capture enzyme immunoassay that uses enzyme-labeled antigen.

H Seppänen

Labsystems Research Laboratories, Helsinki, Finland.

ABSTRACT

An enzyme immunoassay (EIA) for serum immunoglobulin M (IgM) antibodies to rubella virus based on enzyme labeling of viral antigen was developed. The sensitivity of the EIA for the detection of recent rubella virus infection was evaluated by using 115 rubella-IgM-antibody-positive serum specimens, which were confirmed as positive by Rubazyme M (Abbott Diagnostics). In addition, 12 individuals, 2 of whom were exposed to rubella through vaccination and 10 of whom were exposed through natural infection, were studied, and the results were compared with those obtained by indirect EIA (Rubelisa M; Electro-Nucleonics, Inc.) and immunoblotting. The sensitivity of the newly developed EIA with sera from these individuals was 100%. Serum specimens from two patients indicated that the IgM antibodies were detected by the newly developed EIA at the same time as IgM antibodies were detected by immunoblotting and before positive reactions were detected by an indirect EIA. The reference population consisted of 564 healthy blood donors and hospitalized patients (150 serum specimens). In addition, 145 serum specimens commonly giving false-positive reactions in conventional rubella IgM EIAs were studied. With these specimens, no false-positive reactions were observed. Positive IgM responses, which could not be confirmed by immunoblotting, were observed in two samples from the reference population. However, these two samples were rubella IgG positive. The overall specificity of the EIA was 99.8%.


J Clin Microbiol. 1990 April; 28(4): 719-723







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1990 by the American Society for Microbiology. All rights reserved.