JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Starkey, C A
Right arrow Articles by Proffitt, M R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Starkey, C A
Right arrow Articles by Proffitt, M R

 Previous Article  |  Next Article 

J Clin Microbiol. 1990 April; 28(4): 819-822

Evaluation of the Recombigen HIV-1 Latex Agglutination Test.

C A Starkey, B Yen-Lieberman and M R Proffitt

Department of Microbiology, Cleveland Clinic Foundation, Ohio 44195.

ABSTRACT

The Recombigen HIV-1 Latex Agglutination (LA) Test was recently licensed by the U.S. Food and Drug Administration for use as a rapid screening assay for human immunodeficiency virus type 1 (HIV-1) antibodies. However, its performance in various settings and in different populations has not been firmly established. Consequently, we evaluated the test in the Cleveland Clinic Retrovirus Laboratory, a regional reference laboratory for HIV diagnostic testing and a testing laboratory for the Ohio Department of Health Anonymous HIV Testing and Counseling Program. Serum samples from 93 individuals presumed to be at high risk for HIV infection were evaluated. The sera were initially tested for HIV antibodies by enzyme-linked immunosorbent assay (ELISA). All repeatedly reactive sera were subjected to confirmatory Western blot (WB; immunoblot) testing. Of 97 serum specimens tested (5 were from one seroconverter), 44 were repeatedly reactive by ELISA and 53 were nonreactive. Of the reactive serum specimens, 31 were confirmed positive and 12 were indeterminate by WB. All of the sera were coded and then retested by the LA test. Of 53 serum specimens nonreactive by ELISA, 51 were also nonreactive in the LA test. Of the 44 serum specimens reactive by ELISA, 16 were nonreactive by LA; however, 3 of the latter were WB positive. No serum specimen with an ELISA ratio (specimen optical density/cutoff optical density) of less than 2.1 scored reactive in the LA test. The LA test was positive for only two of five consecutive serum specimens from a seroconverter despite the fact that all but the earliest of these were ELISA reactive and WB positive. Although the LA test appears to be an adequate first-line screening test when appropriately used according to the directions of the manufacturer, our data suggest that occasional sera with low levels of reactivity by ELISA may not be readily detected as reactive by the LA test.


J Clin Microbiol. 1990 April; 28(4): 819-822







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1990 by the American Society for Microbiology. All rights reserved.