JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Daley, C
Right arrow Articles by Wilkinson, I
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Daley, C
Right arrow Articles by Wilkinson, I

 Previous Article  |  Next Article 

J Clin Microbiol. 1990 July; 28(7): 1586-1590

Comparative evaluation of nonradiometric BACTEC and improved oxoid signal blood culture systems in a clinical laboratory.

C Daley, I Lim, J Modra and I Wilkinson

Division of Clinical Microbiology, Institute of Medical and Veterinary Science, Adelaide, South Australia.

ABSTRACT

The BACTEC NR660 blood culture system, which uses infrared spectroscopy to detect carbon dioxide generated by bacterial growth, was compared with the new medium formulation of the Oxoid Signal system. Two trials were conducted: a comparative study of 88 organisms in simulated blood cultures and a clinical trial of 3,321 paired patient blood culture samples. Both trials showed that overall the BACTEC system performed better in the recovery of organisms. The Oxoid system was unable to detect by signal the growth of the majority of yeasts, nonfermentative gram-negative bacilli, Neisseria meningitidis, Nocardia spp., and Corynebacterium jeikeium. There were no significant differences in the yield of Staphylococcus spp., members of the family Enterobacteriaceae, Streptococcus spp., or anaerobic organisms. BACTEC detected growth more quickly than did the Oxoid system; 61% of the isolates were detected by BACTEC at 24 h, while 49% of the isolates were detected by Oxoid. The Oxoid system had a high proportion (58.5%) of false-positives, compared with 7.7% for the BACTEC system. Despite the new medium formulation of the Oxoid system, its performance is still not equivalent to that of the BACTEC system.


J Clin Microbiol. 1990 July; 28(7): 1586-1590