JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Freney, J
Right arrow Articles by Fleurette, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Freney, J
Right arrow Articles by Fleurette, J
J Clin Microbiol. 1991 January; 29(1): 38-41

Evaluation of API Coryne in comparison with conventional methods for identifying coryneform bacteria.

J Freney, M T Duperron, C Courtier, W Hansen, F Allard, J M Boeufgras, D Monget and J Fleurette

Laboratoire de Bactériologie, Faculté de Pharmacie, Lyon, France.

ABSTRACT

A study was performed to evaluate a new manual miniaturized system, API Coryne (API-bioMérieux, Inc., La Balme les Grottes, France), in which conventional biochemical methods were used to identify 240 isolates of coryneform and related bacteria. A total of 40% of the isolates were excluded from the study because they could not be identified by conventional methods. Identifications of the 240 isolates obtained with API Coryne showed a 97.6% concordance with conventional methods (79% after 24 h of incubation, 21% after 48 h of incubation): 158 (65.8%) isolates were identified with no further testing, and extra testing was required for 76 (31.8%) isolates. In three (1.2%) cases, the organisms did not correspond to any key in the code book and could not be identified by the computer service of the manufacturer. Only three (1.2%) strains were misidentified. The system was shown to be reliable and rapid when compared with standard identification methods.


J Clin Microbiol. 1991 January; 29(1): 38-41