JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Celig, D M
Right arrow Articles by Schreckenberger, P C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Celig, D M
Right arrow Articles by Schreckenberger, P C
J Clin Microbiol. 1991 March; 29(3): 457-462

Clinical evaluation of the RapID-ANA II panel for identification of anaerobic bacteria.

D M Celig and P C Schreckenberger

Clinical Microbiology Laboratories, University of Illinois Hospital, Chicago.

ABSTRACT

The accuracy of the RapID-ANA II system (Innovative Diagnostic Systems, Inc., Atlanta, Ga.) was evaluated by comparing the results obtained with that system with results obtained by the methods described by the Virginia Polytechnic Institute and State University. Three hundred anaerobic bacteria were tested, including 259 clinical isolates and 41 stock strains of anaerobic microorganisms representing 16 genera and 48 species. When identifications to the genus level only were included, 96% of the anaerobic gram-negative bacilli, 94% of the Clostridium species, 83% of the anaerobic, nonsporeforming, gram-positive bacilli, and 97% of the anaerobic cocci were correctly identified. When correct identifications to the genus and species levels were compared, 86% of 152 anaerobic gram-negative bacilli, 76% of 34 Clostridium species, 81% of 41 anaerobic, nonsporeforming, gram-positive bacilli, and 97% of 73 anaerobic cocci were correctly identified. Eight isolates (3%) produced inadequate identification in which the correct identification was listed with one or two other possible choices and extra tests were required for separation. A total of 9 isolates (3%) were misidentified by the RapID-ANA II panel. Overall, the system was able to correctly identify 94% of all the isolates to the genus level and 87% of the isolates to the species level in 4 h by using aerobic incubation.


J Clin Microbiol. 1991 March; 29(3): 457-462