JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Arduino, M J
Right arrow Articles by Favero, M S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Arduino, M J
Right arrow Articles by Favero, M S
J Clin Microbiol. 1991 March; 29(3): 592-594

Comparison of microbiologic assay methods for hemodialysis fluids.

M J Arduino, L A Bland, S M Aguero, L Carson, M Ridgeway and M S Favero

Nosocomial Infections Laboratory Branch, Centers for Disease Control, Atlanta, Georgia 30333.

ABSTRACT

To help prevent pyrogenic reactions and bacteremia in hemodialysis patients, the Association for the Advancement of Medical Instrumentation and the Centers for Disease Control recommend microbiologic assay of hemodialysis fluids at least monthly. Five commercially available assay systems were evaluated by using the membrane filtration technique with standard methods agar and trypticase soy agar as the standards for comparison. Each assay system was challenged with dialysate and reverse-osmosis water from local dialysis centers, aqueous suspensions of eight laboratory strains of gram-negative bacilli and nontuberculous mycobacteria, and a mixed microbial flora inoculated into reverse-osmosis water and laboratory-prepared dialysate. Mean viable counts from triplicate samples were obtained after incubation at 37 degrees C for up to 72 h. The efficiency of recovery varied with the specific type of microbial challenge. The SPC water sampler (Millipore Corp., Bedford, Mass.) was the most consistent in obtaining the highest viable counts. Other commercial systems were comparable to each other in overall performance. All assay systems tested provided an acceptable balance between microbial recovery and required sampling time, equipment, and expertise.


J Clin Microbiol. 1991 March; 29(3): 592-594