ABSTRACT
Routine monitoring of antibiotic resistance at Children's Hospital, Boston, detected a dramatic increase in the prevalence of imipenem-resistant strains of Pseudomonas aeruginosa. Further studies documented that false resistance to imipenem was due, in part, to the loss of imipenem potency in customized MIC microdilution trays supplied by Sensititre Ltd. (West Sussex, United Kingdom). Recognition of the problem was delayed by use of the quality control standard recommended by the manufacturer, which were higher and broader than those suggested by the National Committee for Clinical Laboratory Standards.
J Clin Microbiol. 1991 April; 29(4): 827-829
This article has been cited by other articles:
-
Steward, C. D., Mohammed, J. M., Swenson, J. M., Stocker, S. A., Williams, P. P., Gaynes, R. P., McGowan, J. E. Jr., Tenover, F. C.
(2003). Antimicrobial Susceptibility Testing of Carbapenems: Multicenter Validity Testing and Accuracy Levels of Five Antimicrobial Test Methods for Detecting Resistance in Enterobacteriaceae and Pseudomonas aeruginosa Isolates. J. Clin. Microbiol.
41: 351-358
[Abstract]
[Full Text]
-
Gershon, A. S., de Azavedo, J. C. S., McGeer, A., Ostrowska, K. I., Church, D., Hoban, D. J., Harding, G. K. M., Weiss, K., Abbott, L., Smaill, F., Gourdeau, M., Murray, G., Low, D. E.
(2002). Activities of New Fluoroquinolones, Ketolides, and Other Antimicrobials against Blood Culture Isolates of Viridans Group Streptococci from across Canada, 2000. Antimicrob. Agents Chemother.
46: 1553-1556
[Abstract]
[Full Text]
-
Joyanes, P., del Carmen Conejo, M., Martinez-Martinez, L., Perea, E. J.
(2001). Evaluation of the VITEK 2 System for the Identification and Susceptibility Testing of Three Species of Nonfermenting Gram-Negative Rods Frequently Isolated from Clinical Samples. J. Clin. Microbiol.
39: 3247-3253
[Abstract]
[Full Text]
-
Tsakris, A., Pantazi, A., Pournaras, S., Maniatis, A., Polyzou, A., Sofianou, D.
(2000). Pseudo-Outbreak of Imipenem-Resistant Acinetobacter baumannii Resulting from False Susceptibility Testing by a Rapid Automated System. J. Clin. Microbiol.
38: 3505-3507
[Abstract]
[Full Text]
-
Cantón, R., Pérez-Vázquez, M., Oliver, A., Sánchez Del Saz, B., Gutiérrez, M. O., Martínez-Ferrer, M., Baquero, F.
(2000). Evaluation of the Wider System, a New Computer-Assisted Image-Processing Device for Bacterial Identification and Susceptibility Testing. J. Clin. Microbiol.
38: 1339-1346
[Abstract]
[Full Text]
-
Carmeli, Y., Eichelberger, K., Soja, D., Dakos, J., Venkataraman, L., DeGirolami, P., Samore, M.
(1998). Failure of Quality Control Measures To Prevent Reporting of False Resistance to Imipenem, Resulting in a Pseudo-Outbreak of Imipenem-Resistant Pseudomonas aeruginosa. J. Clin. Microbiol.
36: 595-597
[Abstract]
[Full Text]
Copyright © 1991 by the American Society for Microbiology. All rights reserved.