JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ferreira-da-Cruz, M F
Right arrow Articles by Daniel-Ribeiro, C T
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ferreira-da-Cruz, M F
Right arrow Articles by Daniel-Ribeiro, C T
J Clin Microbiol. 1991 June; 29(6): 1202-1205

Sensitive immunoradiometric assay for the detection of Paracoccidioides brasiliensis antigens in human sera.

M F Ferreira-da-Cruz, B Galvão-Castro and C T Daniel-Ribeiro

Department of Immunology, Oswaldo Cruz Foundation, Rio de Janeiro, Brazil.

ABSTRACT

In the present study we report the standardization of an immunoradiometric assay (IRMA) for detection of Paracoccidioides brasiliensis circulating antigens that could be useful in the diagnosis and prognosis of paracoccidioidomycosis. For this purpose we studied the reactivities of P. brasiliensis and other mycotic antigens with rabbit polyclonal anti-P. brasiliensis antibodies (immunoglobulin G) in order to evaluate the sensitivity and specificity of an IRMA for detecting P. brasiliensis antigens. The results were compared with those obtained by the double immunodiffusion test, the standard technique for the serodiagnosis of paracoccidioidomycosis. By using the immunoglobulin G fraction of rabbit antisera (900 ng per well), it was possible to detect up to 3.6 ng (0.12 micrograms/ml) of cellular antigen and 360 ng (12 micrograms/ml) of metabolic antigen in contrast to the double immunodiffusion test that could detect only 12 micrograms (1.2 mg/ml) of both antigens. IRMA was shown to be feasible and very sensitive and may therefore help, together with clinical data, in establishing early diagnosis and assessing disease activity. It could also allow the study of relationships between P. brasiliensis circulating antigens and host defense mechanisms during the disease.


J Clin Microbiol. 1991 June; 29(6): 1202-1205




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1991 by the American Society for Microbiology. All rights reserved.