J Clin Microbiol. 1991 July; 29(7): 1422-1428
Comparison of the autoSCAN-W/A rapid bacterial identification system and the Vitek AutoMicrobic system for identification of gram-negative bacilli.
M A Pfaller,
D Sahm,
C O'Hara,
C Ciaglia,
M Yu,
N Yamane,
G Scharnweber and
D Rhoden
Iowa City Veteran's Affairs Medical Center, Iowa.
ABSTRACT
The autoSCAN-W/A (W/A; Baxter MicroScan, West Sacramento, Calif.) with the new fluorometric Rapid Neg Combo 1 (RNC) panel is a fully automated fluorometric system for identification of both enteric and nonenteric gram-negative bacilli within 2 h. We compared the W/A with the Vitek AutoMicrobic System (Vitek AMS; Vitek Systems, Inc., Hazelwood, Mo.) for identification of 383 clinical isolates of gram-negative bacilli. The API 20E (Analytab Products, Plainview, N.Y.) and conventional biochemical testing were used as the reference systems. The W/A correctly identified 336 isolates (87.7%) to the species level and classified an additional 29 isolates (7.6%) as correct with low probability (overall identification = 95.3%); the Vitek AMS correctly identified 355 isolates (92.7%) to the species level and classified an additional 8 isolates (2.1%) as correct with low probability (overall identification = 94.8%). A common set of 134 isolates of gram-negative bacilli was tested in both participating laboratories as a means of assessing interlaboratory agreement with both the W/A and the Vitek AMS. The overall agreements between the two laboratories were 86% with the W/A and 92% with the Vitek AMS. The W/A performed comparably to the Vitek AMS for identification of most gram-negative bacilli, actually exceeding the Vitek AMS for identification of nonenteric bacilli. Rapid time to identification and a high level of automation make the W/A an attractive system for clinical microbiology laboratories.
J Clin Microbiol. 1991 July; 29(7): 1422-1428
This article has been cited by other articles:
-
Donay, J.-L., Mathieu, D., Fernandes, P., Pregermain, C., Bruel, P., Wargnier, A., Casin, I., Weill, F. X., Lagrange, P. H., Herrmann, J. L.
(2004). Evaluation of the Automated Phoenix System for Potential Routine Use in the Clinical Microbiology Laboratory. J. Clin. Microbiol.
42: 1542-1546
[Abstract]
[Full Text]
-
Leclercq, A., Lambert, B., Pierard, D., Mahillon, J.
(2001). Particular Biochemical Profiles for Enterohemorrhagic Escherichia coli O157:H7 Isolates on the ID 32E System. J. Clin. Microbiol.
39: 1161-1164
[Abstract]
[Full Text]
-
Sung, L. L., Yang, D. I., Hung, C. C., Ho, H. T.
(2000). Evaluation of autoSCAN-W/A and the Vitek GNI+ AutoMicrobic System for Identification of Non-Glucose-Fermenting Gram-Negative Bacilli. J. Clin. Microbiol.
38: 1127-1130
[Abstract]
[Full Text]
-
Odumeru, J. A., Steele, M., Fruhner, L., Larkin, C., Jiang, J., Mann, E., McNab, W. B.
(1999). Evaluation of Accuracy and Repeatability of Identification of Food-Borne Pathogens by Automated Bacterial Identification Systems. J. Clin. Microbiol.
37: 944-949
[Abstract]
[Full Text]
-
Funke, G., Monnet, D., deBernardis, C., von Graevenitz, A., Freney, J.
(1998). Evaluation of the VITEK 2 System for Rapid Identification of Medically Relevant Gram-Negative Rods. J. Clin. Microbiol.
36: 1948-1952
[Abstract]
[Full Text]
-
Denton, M., Kerr, K. G.
(1998). Microbiological and Clinical Aspects of Infection Associated with Stenotrophomonas maltophilia. Clin. Microbiol. Rev.
11: 57-80
[Abstract]
[Full Text]
Copyright © 1991 by the American Society for Microbiology. All rights reserved.