JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by O'Hara, C M
Right arrow Articles by Miller, J M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by O'Hara, C M
Right arrow Articles by Miller, J M
J Clin Microbiol. 1992 January; 30(1): 123-125

Reevaluation of the API 20E identification system versus conventional biochemicals for identification of members of the family Enterobacteriaceae: a new look at an old product.

C M O'Hara, D L Rhoden and J M Miller

Hospital Infections Program, Centers for Disease Control, Atlanta, Georgia 30333.

ABSTRACT

The API 20E bacterial identification system has been used for 19 years, often as the standard with which other identification systems are compared. Because the accuracy of this system compared with conventional biochemical tests has not been determined in many years, we evaluated the API 20E linear strip by using 291 typical and atypical strains of the family Enterobacteriaceae taken from a culture collection. At 24 h, the API 20E correctly identified by genus and species 229 of 291 (78.7%) of the strains, using Salmonella and Shigella serotyping where indicated. At 48 h, 95.2% were correctly identified by using additional biochemical tests as recommended by the manufacturer. The API 20E misidentified eight (2.7%) strains; these strains were not limited to any particular genus. When 81 of these Enterobacteriaceae strains were arranged into a weighted assortment correlating to the frequency with which they might be found in a clinical laboratory, the API 20E correctly identified 71 (87.7%) at 24 h and 78 (96.3%) at 48 h. This evaluation concluded that the accuracy of the identification of Enterobacteriaceae strains at 24 h (78.7%) may be significantly lower than that of earlier evaluations. However, there is no significant difference in the ability of the API 20E to correctly identify "challenge" type organisms (229 of 291) versus routine hospital isolates (71 of 81) (P greater than 0.05), but the system is not as accurate as the conventional biochemical method of identification.


J Clin Microbiol. 1992 January; 30(1): 123-125




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1992 by the American Society for Microbiology. All rights reserved.