J Clin Microbiol. 1992 January; 30(1): 63-66
Controlled evaluation of BACTEC PLUS 27 and Roche Septi-Chek anaerobic blood culture bottles.
M L Wilson,
L J Harrell,
S Mirrett,
M P Weinstein,
C W Stratton and
L B Reller
Clinical Microbiology Laboratory, Duke University Medical Center, Durham, North Carolina.
ABSTRACT
Becton Dickinson Diagnostic Instrument Systems (Sparks, Md.) recently introduced BACTEC high-volume aerobic and anaerobic bottles that accept up to 10 ml of blood for use on their nonradiometric blood culture instruments. Both bottles contain 25 ml of tryptic soy broth, 0.05% sodium polyanetholesulfonate, and mixed resins. We compared the anaerobic bottle, designated BACTEC PLUS 27 (BP27), with the Roche Septi-Chek (RSC) Columbia broth anaerobic bottle in a collaborative evaluation at three university hospitals. A total of 5,152 adequately filled blood cultures were obtained from adult patients with suspected bacteremia or fungemia. Staphylococcus aureus was recovered significantly more often (P less than 0.03) from BP27 bottles alone; there were no other significant differences in yield. When microorganisms were recovered from both anaerobic bottles, growth was detected earlier in BP27 than it was in RSC (P less than 0.001), especially for S. aureus (P less than 0.001) and Staphylococcus epidermidis (P less than 0.02). We conclude that the yield from BP27 bottles is equivalent to or better (S. aureus) than that from RSC anaerobic bottles with Columbia broth and that speed of detection is superior with BP27 bottles.
J Clin Microbiol. 1992 January; 30(1): 63-66
This article has been cited by other articles:
-
Baddour, L. M., Wilson, W. R., Bayer, A. S., Fowler, V. G. Jr, Bolger, A. F., Levison, M. E., Ferrieri, P., Gerber, M. A., Tani, L. Y., Gewitz, M. H., Tong, D. C., Steckelberg, J. M., Baltimore, R. S., Shulman, S. T., Burns, J. C., Falace, D. A., Newburger, J. W., Pallasch, T. J., Takahashi, M., Taubert, K. A.
(2005). Infective Endocarditis: Diagnosis, Antimicrobial Therapy, and Management of Complications: A Statement for Healthcare Professionals From the Committee on Rheumatic Fever, Endocarditis, and Kawasaki Disease, Council on Cardiovascular Disease in the Young, and the Councils on Clinical Cardiology, Stroke, and Cardiovascular Surgery and Anesthesia, American Heart Association: Endorsed by the Infectious Diseases Society of America. Circulation
111: e394-e434
[Abstract]
[Full Text]
-
Mirrett, S., Petti, C. A., Woods, C. W., Magadia, R., Weinstein, M. P., Reller, L. B.
(2004). Controlled Clinical Comparison of the BacT/ALERT FN and the Standard Anaerobic SN Blood Culture Medium. J. Clin. Microbiol.
42: 4581-4585
[Abstract]
[Full Text]
-
Wilson, M. L., Mirrett, S., Meredith, F. T., Weinstein, M. P., Scotto, V., Reller, L. B.
(2001). Controlled Clinical Comparison of BACTEC Plus Anaerobic/F to Standard Anaerobic/F as the Anaerobic Companion Bottle to Plus Aerobic/F Medium for Culturing Blood from Adults. J. Clin. Microbiol.
39: 983-989
[Abstract]
[Full Text]
-
Wilson, M. L., Mirrett, S., McDonald, L. C., Weinstein, M. P., Fune, J., Reller, L. B.
(1999). Controlled Clinical Comparison of bioMerieux VITAL and BACTEC NR-660 Blood Culture Systems for Detection of Bacteremia and Fungemia in Adults. J. Clin. Microbiol.
37: 1709-1713
[Abstract]
[Full Text]
Copyright © 1992 by the American Society for Microbiology. All rights reserved.